AC100-240V 1 CH Remote Control Set Delay Control Industrial Motor Oxygenator Irrigation Lighting Universal Water Pump Pumping

 

Feature:
-433MHZ Frequency and fixed / learning code, stable transmission.
-With high reliability and low power consumption.
-The program uses automatically partial code, effectively overcome the traditional shortcomings of remote control code.
-Compact design with key-chain, easy to carry.

Basic parameters and functions: The countdown wireless remote control switch is programmed independently by a microcontroller, with strong anti-interference ability and stable data transmission. It is easy and fast to learn codes with a single key, and can set any delay function from 1-999 minutes. It is very suitable for controlling equipment such as water pumps.

Application Field:Applications in motor control, fish pond oxygenation control, garden irrigation and ventilation, and other agricultural applications.

 

Receiver

Operating voltage: AC110-240V

Operating frequency: 433MHz

Load current: ≤30A

Standby current: <10mA

Shell material: ABS

Receiving sensitivity: -105dBm

Size: 130*86.6*45mm

Weight: 160g

 

Transmitter (Remote Control)

Working Voltage:DC9V

Load current: <30A

Standby current: 0mA

Modulation mode: ASK

Signal frequency: 433MHz

Shell material: ABS

Size: 136*42*25mm

Weight: 93g

 

Basic information
Operating voltage: AC110-240V
Operating frequency: 433MHz
Load current: ≤30A
Standby current: <10mA
Shell material: ABS
Receiving sensitivity: -105dBm

Instruction

(1)Key Description:

Learning Key: Press this key to learn the code and the indicator light will light up, indicating that it has entered the learning code state.

Setting Key: Press this key to set the delay time of ones digit, tens digit, hundreds digit.

Time Key: Press this key to adjust the delay time in ones digit, tens digit, hundreds digit.

On/Off Key: Press this key once, the switch starts to work, and press this key again, the switch stops working.

 

(2)Learning Methods:

Press the learning key until the learning indicator light is on, and then press the Abutton on the remote control, the learning indicator light flashes 3 times, indicating that the learning code is successful.

 

This controller can learn at most 20 sets of remote control codes, and  the earliest learned remote control codes will be automatically cleared after more than 20 sets.

 

(3) Delay Setting Description:

Press the setting key to select the ones digit/tens digit/hundreds digit, when you select ones digit, tens digit or hundreds digit, the LED digital screen will flash. After selecting the digit, press the time key to increase the number of the digital.

After adjusting the time, press the setting key to exit the delay setting. ( The delay time is in minutes, and can be set from 1 to 999 minutes, and the number of ones digit, tens digit, hundreds digit is increased repeatedly from 0 to 9.)

 

(eg. If you want to set 12 minutes, press the setting key once, and the ones digit will flash, then press the time key to adjust the ones digit to 2, press the setting button again, the tens digit will flash, press the time key to adjust the tens digit to 1, and then press the setting key again to exit the delay setting. At this time, the delay time is 12 minutes, and the device will

automatically turn off after 12 minutes.)

 

(4) Manual Control Operation:

After setting the delay time, press the On/Off key once, the receiver starts to work, when the delay time returns to 0on the LED digital screen, the receiver stops working.

 

(5) Remote Control Operation:

After setting the delay time and learning the remote control, press the remote control Abutton once, the receiver starts to work, and when the delay time returns to 0on the LED digital screen , the receiver stops working. If press the Bbutton on the remote control during the delay time, the receiver also stops working.

 

(6)Clearing Code:

Press and hold the learning key for 5 seconds, the learning indicator light flashes, indicating that the clearing code is successful.

Order: 

We try our best to describe the products in details as possible as we could. If you still have the question, pls don't hesitate to contact us.

Payment: 
1. Paypal: (www.paypal.com)
You can directly pay this payment to our paypal account:
 sale@einausschalten.com . Or you also can tell us your PayPal account, we will send a bill to you via PayPal.

2.You can also pay the payment by MasterCard and VISA.

(1) Choose to pay with your credit card in PayPal.

(2) We will send you an email for the payment request, and you can pay for your order through that email by a MasterCard or VISA.

Delivery:
We will deliver directly the parcel to your delivery address as soon as we receive your full payment. 
For high valued products, we may require the verification of your mailing address before the delivery. 
All items are carefully checked and well packed before the dispatch. 
Delivery methods:
1. Airmail: 7~15 working days (If your products has the battery, it will take 10-25 working days.)
2. Door to door Express: 3~9 working days, For example: EMS, DHL, UPS, Fedex, etc.

Returns:
Defective and missing parts: If you receive an item that is defective, or not the item you ordered, or was damaged in shipping, pls send back to us within 7 days from the date of receipt. 
The item must be returned to us in its original and unused condition with its original box, packaging material, contents, and accessories. 
In case of the missing parts, please notify us on the same day once you receive the product.

Customs duties or import taxes:
You might have to pay an amount charged by your Customs including ( and not limited to) the duties, taxes or any other extra fees collected by courier company or postal services.

(1) If you choose to transport by package, you don’t need to pay any customs fees.
(2) If you choose express transportation, such as DHL, UPS, etc. When you receive the package, you typically don’t have to pay tariffs. But if you pay the tariff, please contact us and send us the tariff bill, we will return you the same amount of cash voucher, you can use this voucher to purchase any products of us.

B2B:
Though we are online retailer, we're also looking to develop relationships with B2B clients and will provide customerized products based on your requirements.

Customer oriented Service:
To satisfy customer's requirements is our priority. We sincerely hope that you will enjoy a cheerful online shopping experience with us.
If you have questions about our products or the website, pls don't hesitate to contact us.

Contact Us:

Please contact us with any comments, questions or suggestions that you may have, we will be happy to assist you.

Bulk Orders
 
Besides retail orders, we also accept bulk orders. If you have any queries or questions, please do not hesitate to contact us with following Contact Us Form. We will give you a favourable discount price according to your order quantity.



Company:

Lejing Industry Development Co., Ltd.

 

Adresse:
You Yuan Xin Cun
Meilong Straße, Longhua
Shenzhen, Guangdong
China518,000

E-Mailsale@einausschalten.com

Whatsapp: +86 183 2644 0199

Phone number: +86 183 2644 0199

Youtube ID: Einausschalten


Newsletter: